Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Raw-Materials Traceability
The supplier has traceability identification of raw materials
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 17 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
  • Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
  • Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
  • Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
  • Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
  • Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
Find Similar Products

Basic Info.

Model NO.
ID511XX
Weighing
30-300kg
Accuracy
0.1g
Display Type
LED
Display Digits
6 digits
Measure Method
Semi-Automatic
Shell Material
Stainless Steel
Application
Commercial
Customized
Customized
Transport Package
Carton
Trademark
Webowt
Origin
China
HS Code
8423900010
Production Capacity
50000 Pieces/Year

Product Description

  1. Experience the brilliance of a 7-bit LED display, designed to provide clear and precise readings in any environment.
  2. Enjoy seamless operation with support for 1 analog scale input, capable of accommodating up to 12 load cells for versatile applications.
  3. Certification: CPA 6000e, offering unmatched precision with a division capability of up to 150,000 for superior accuracy.
  4. Equipped with dual standard serial ports: 2 RS232 + RS232/485, or 2 RS232 + RS485, complemented by a LAN port for enhanced connectivity.
  5. Standard configuration supports robust communication protocols including MODBUS-RTU and MODBUS-TCP (available in the Ethernet version).
  6. Expand your system capabilities with an optional PLC communication interface for seamless integration.
  • Connect effortlessly with PROFIBUS-DP for Siemens PLCs and CC-link for Mitsubishi PLCs, ensuring compatibility with leading systems.
  • Leverage the power of PROFINET with dual LAN ports and a built-in switch tailored for Siemens PLCs, offering unparalleled network efficiency.
  • Maximize connectivity with EtherNet/IP featuring dual LAN ports and a built-in switch, compatible with Rockwell and Delta PLCs.
  • Precision in every measure with 16-bit DAC supporting 1 scale at 4-20 mA or dual scales at 4-20 mA, ensuring high-resolution output.
  1. Optimize operations with optional I/O (input/output) configurations for tailored functionality.
  • Versatile control with 8 input and 12 output channels, designed for comprehensive operational support.
  1. Benefit from multiple calibration modes to ensure accuracy and reliability in every application.
  • Supports up to 5-point weight calibration and offers the flexibility of calibration without weights for convenience.
  • Enable remote calibration through a PLC communication interface, enhancing ease and efficiency.
  1. Application supports: Comprehensive solutions for varied weighing requirements, ensuring optimized performance.
  • Basic weighing version includes lower/upper limit level detection for dynamic control and safety assurance.
  • Supports dual-speed preset point control with 8 simple comparison outputs for precise management of operations.
  1. Built-in load cell safety barrier allows direct connection to scale platforms in Zone 1 and Zone 2, ensuring safety and compliance.
  2. Efficient power management with a working power supply designed for optimal performance.
Operates on DC 24VDC, with the maximum power consumption of the complete machine being impressively less than 6 W.
Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display

Product selection configuration: Tailor your solution with our flexible configuration options.
Indicator Model Number Shell Type Hardware Sub-item I/O Option PLC Interface Application Sub-items Language Power Supply
ID511XX H C 1 0 0 0 D
ID511XX H: Zone 2 explosion-proof and dustproof housing C: RS232+RS232/485
E: LAN+RS232+RS485
0: None
1: In x 8 / OC Out x 12
3: In x 8 / MOS Out x 12
0: None
A: Scale x 1 4-20mA output
B: Scales x 2 4-20mA output
C: CC-LINK
E: EtherNet/IP
F: PROFINET
G: EtherNet/IP+scale x 1 4-20mA
H: PROFINET+scale x 1 4-20mA
P: PROFIBUS communication interface
T: EtherCAT
U: EtherCAT + scale x 1 4-20mA output
V: PROFIBUS-DP + scale x 1 4-20mA
K: CCLINK IE FB
0: Standard application 0: Chinese
1: English
D: 24VDC no power cable


Common configuration: Access a suite of standard features and configurations designed for universal appeal and utility.
Material No. Configuration Model Configuration Description
851108T ID511XXHC0000D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
851108U ID511XXHE0000D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS485) and 100m LAN port, MODBUS-RTU, MODBUS-TCP, basic application software version, 7-bit LED display, 24VDC no power cable
851108V ID511XXHC1000D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, intrinsically safe explosion-resistant load cell output interface), serial ports x 2 (RS232 + RS232/485), In x 8 / OC Out x 12, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
851108X ID511XXHC0P00D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), PROFIBUS communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
851108Y ID511XXHC0A00D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, intrinsically safe explosion-resistant load cell output interface), serial ports x 2 (RS232 + RS232/485), 4-20 mA analog output interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
851108Z ID511XXHC0B00D ID511, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), 4-20 mA analog output interface x2, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
8511090 ID511XXHC0C00D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), CC-LINK communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
8511091 ID511XXHC0E00D ID511, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), EtherNet/IP communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
8511092 ID511XXHC0F00D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), PROFINET communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable
85110E6 ID511XXHC0T00D ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), MODBUS-RTU, EtherCAT communication interface, basic application software version, 7-bit LED display, 24VDC no power cable
Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display
                      Desktop placement                    Wall bracket installation
Zone 2 Hazardous Area Load Cells Weighing-Indicator with LED DisplayZone 2 Hazardous Area Load Cells Weighing-Indicator with LED DisplayZone 2 Hazardous Area Load Cells Weighing-Indicator with LED DisplayZone 2 Hazardous Area Load Cells Weighing-Indicator with LED DisplayZone 2 Hazardous Area Load Cells Weighing-Indicator with LED Display

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier