Customization: | Available |
---|---|
Type: | Cantilever Beam Load Cell |
For: | Weighing Load Cell |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product type | Model | Elastomer | Capacity (kg) | Certification/Area | Temperature | Accuracy | Cable Length | Backup |
a | b | c | d | e | f | g | h | i |
LW - Load cell D - Digital load cell |
WB702 | Stainless steel 17-4PH | 220,550,1100, 2200,3000,4400 |
N: Standard X: Explosion-proof |
S: Normal | C3, C6, C10 | 3.5m,6m | A: Standard, Threadless F: Customization |
Specifications | |||||||||||||
Model | LWD WB702 | ||||||||||||
Rated capacity (R.C.) | kg | 220 | 550 | 1100 | 2200 | 3000 | 4400 | ||||||
Accuracy | C3 | C6 | C10 | ||||||||||
Zero load output | %R.C. | ≤1.0 | |||||||||||
Comprehensive error | %R.C. | ≤0.023 | ≤0.012 | ≤0.007 | |||||||||
Repeatability error | %A.L. | ≤0.011 | ≤0.005 | ≤0.003 | |||||||||
Creep (30 minutes) | %A.L. | ≤0.023 | ≤0.0116 | ≤0.007 | |||||||||
Minimum static load output recovery value (DR, 30 minutes) | %A.L. | ≤0.023 | ≤0.0116 | ≤0.007 | |||||||||
Temperature Effect | Minimum static load output | % R.C./ºC | ≤0.0011 | ≤0.0007 | ≤0.0007 | ||||||||
sensitivity | % R.C./ºC | ≤0.0010 | ≤0.0005 | ≤0.0003 | |||||||||
Temperature Range | compensate | ºC | -10~+40 | ||||||||||
range of application |
ºC | -20~+55 | |||||||||||
Secure storage temperature | ºC | -40~+80 | |||||||||||
calculate | Maximum Verification Interval (Nmax) | 3000 | 6000 | 10000 | |||||||||
Opposite Vmin(Y) | 9000 | 11000 | 22000 | ||||||||||
Partition coefficient (PLC) | 0.8 | ||||||||||||
Humidity conforms to | CH | ||||||||||||
Minimum static load (Emin) | kg | 0 | |||||||||||
Communication | type | CAN | |||||||||||
protocol | WEBOWT WCAN, open | ||||||||||||
Driving Voltage | Min-Max | V DC | 9~16 | ||||||||||
recommend | V DC | 12 | |||||||||||
Current | maximum | mA | 50 | ||||||||||
recommend | mA | 30 | |||||||||||
Static Electricity Discharge ESD | KV | 8 | |||||||||||
Immunity | V/m | 10 | |||||||||||
Surge Protection | KV | Line line: 1.2KV / Line to ground: 2.2KV | |||||||||||
Burst Of Pulses EFT | KV | power line: +/-3.5kV; signal: +/-2.5kV | |||||||||||
External Part Degree | [email protected]. | 1000000 | 2000000 | 2000000 | |||||||||
Data update rate | Hz | 50 | 50 / 100 / 150 | 50 / 100 / 150 | |||||||||
Status Monitoring and Output | Underload alarm / overload alarm / fault alarm | ||||||||||||
Data Output | Floating point number weight + long integral internal code + alarm status | ||||||||||||
Material | stainless steel | ||||||||||||
surface preparation | electrochemical polish | ||||||||||||
protect | Sealing Method | Welding seal | |||||||||||
Protection Level | IP68 / IP69K | ||||||||||||
limit load | Safe Overload | %R.C. | 150% | ||||||||||
Extreme-overload | %R.C. | 300% | |||||||||||
Cable length | m | 3.5 | 6 | ||||||||||
construction bolt | Bolt size | M12 | M14 | M18 | |||||||||
strength grade | A2-70/8.8 grade and above | ||||||||||||
tightening torque | N-m | 120 | 196 | 300 |
Cable Color | Color Code (4-wire) |
Yellow (Long) | SHILD |
Green | CAN_H |
White | CAN_L |
Red | V+ |
Black | V- |